Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 250
Filtrar
1.
Sleep Adv ; 5(1): zpae016, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38571727

RESUMEN

Study Objectives: Symptom impact and neurocognitive function have not been previously compared between patients with obesity-associated hypoventilation disorders (obesity hypoventilation syndrome [OHS]) and hypoventilation in the setting of obesity and obstructive airways disease (OHAD). The aim of this study is to compare baseline sleep-related symptoms, health-related quality of life, and neurocognitive function between OHS and OHAD and the impact of PAP therapy on these outcomes. Methods: Epworth Sleepiness Scale (ESS), Pittsburgh Sleepiness Quality Index (PSQI), SF36, and various neurocognitive tests, in addition to anthropometric, polysomnography, lung function, and blood gas data from participants with OHS and participants with OHAD, were included in the analysis. These data were originally collected in their respective randomized clinical trials, comparing the efficacy of different PAP modes (bilevel PAP vs. CPAP) in resolving hypercapnia. Between groups (OHS vs OHAD), pre- and post-treatment (with 3 months of positive airway pressure) comparisons were made using linear mixed modeling. Results: 45 OHS participants (mean age 51 years old, 33% female, BMI 52 kg/m2, FER 0.81, PaCO2 54 mmHg, AHI 87/h) and 32 OHAD participants (mean age 61years old, 31% female, BMI 43kg/m2, FER 0.60, PaCO2 54 mmHg, AHI 59/h) were included in the analysis. Both OHS and OHAD had similar baseline ESS (14(5.6) vs. 12(5.4)), Global PSQI (10(3.2) vs. 11(4.8)), SF36 and neurocognitive test performances (other than OHAD had lower digit symbol substitution test performance). Treatment with PAP therapy resulted in similar ESS, Global PSQI, and SF36 improvements in both groups. Neurocognitive performance did not significantly improve after PAP therapy in either group. Conclusions: The symptom impact between two separate hypoventilation disorders (OHS and OHAD), in terms of sleepiness, sleep quality, quality of life, and cognitive function, were similar. OHS and OHAD had similar treatment responses in these parameters after 3 months of PAP therapy.Nocturnal ventilatory support in OHS.

2.
Clin Obes ; : e12651, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38419261

RESUMEN

Obstructive sleep apnea is a common comorbidity that occurs in individuals with obesity. It classically manifests with excessive daytime sleepiness, resulting in reduced quality of life, workplace productivity, and an increased risk of motor vehicle accidents. Weight gain plays an important role in its pathogenesis through worsening upper airway collapsibility, and current treatment options are targeted towards mechanically overcoming upper airway obstruction and weight loss. Continuous positive airway pressure therapy remains the most widely prescribed treatment for obstructive sleep apnea but poor tolerance is a common barrier to effective treatment. Sustainable weight loss is an important treatment option but can be difficult to achieve without bariatric surgery. The recent advances in incretin-based pharmacotherapies represent a promising avenue not only in achieving long-term weight loss but also in treating obstructive sleep apnoea and alleviating the burden of its symptoms and comorbidities.

3.
Drug Test Anal ; 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38414100

RESUMEN

Point-of-collection testing (POCT) devices are widely used in roadside and workplace drug testing to identify recent cannabis use by measuring the presence of Δ9 -tetrahydrocannabinol (THC) in oral fluid (OF). However, the performance of POCT devices with oral medicinal cannabis products remains poorly described. In a randomised, double-blinded, crossover trial, adults with insomnia disorder (n = 20) received a single (2 mL) oral dose of oil containing 10 mg THC + 200 mg cannabidiol, or placebo, prior to sleep. Participants were tested with the Securetec DrugWipe® 5S (10 ng/mL THC cut-off) and Dräger DrugTest® 5000 (25 ng/mL THC cut-off) POCT devices at baseline (pre-treatment) and then at 0.5, 10, and 18 h post-treatment. An OF sample, taken at each time point, was also analysed using liquid chromatography-tandem mass spectrometry. Large individual variability in OF THC concentrations was observed 0.5 h post-treatment (range: 0-425 ng/mL; mean (SD) 48.7 (107.5) ng/mL). Both the Securetec DrugWipe® 5S and DrugTest® 5000 demonstrated poor sensitivity to THC at 0.5 h post-treatment (25% and 50%, respectively). At 10 and 18 h post-treatment, all participant OF THC concentrations were below screening cut-offs, and all test results were negative. These findings highlight the relatively poor sensitivity of both devices in detecting recent use of an oral medicinal cannabis product. They also suggest a low probability of obtaining a positive THC result the morning after ('one-off') use. Further research is required to establish the probability of obtaining a positive THC result with regular medicinal cannabis use.

4.
Sleep ; 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38394454

RESUMEN

STUDY OBJECTIVES: In older adults with Alzheimer's disease, slowing of electroencephalographic (EEG) activity during REM sleep has been observed. Few studies have examined EEG slowing during REM in those with mild cognitive impairment (MCI) and none have examined its relationship with cognition in this at-risk population. METHODS: 210 older adults (mean age = 67.0, sd = 8.2 years) underwent comprehensive neuropsychological, medical, and psychiatric assessment and overnight polysomnography. Participants were classified as subjective cognitive impairment (SCI; n=75), non-amnestic MCI (naMCI, n=85), and amnestic MCI (aMCI, n=50). REM EEG slowing was defined as (delta + theta) / (alpha + sigma + beta) power and calculated for frontal, central, parietal, and occipital regions. Analysis of variance compared REM EEG slowing between groups. Correlations between REM EEG slowing and cognition, including learning and memory, visuospatial and executive functions, were examined within each subgroup. RESULTS: The aMCI group had significantly greater REM EEG slowing in the parietal and occipital regions compared to the naMCI and SCI groups (partial η2 = 0.06, p<0.05 and 0.06, p<0.05, respectively), and greater EEG slowing in the central region compared to SCI group (partial η2 = 0.03, p<0.05). Greater REM EEG slowing in parietal (r = -0.49) and occipital regions (r = -0.38 (O1/M2) and -0.33 (O2/M1) were associated with poorer visuospatial performance in naMCI. CONCLUSION: REM EEG slowing may differentiate older adults with memory impairment from those without. Longitudinal studies are now warranted to examine the prognostic utility of REM EEG slowing for cognitive and dementia trajectories.

5.
Contemp Clin Trials ; 137: 107424, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38145713

RESUMEN

There is accumulating evidence that has linked OSA with increased risk of cognitive decline and dementia. Here we present the protocol for an Australian, multi-site randomised controlled, parallel open-label trial which will evaluate the feasibility for a full-scale trial investigating the effects of treating OSA on cognitive decline in older adults at risk of dementia within memory clinic settings. We will randomise 180 older adults to either the treatment intervention group or control group for 2 years. Inclusion criteria include: 50-85 years; mild-severe OSA (defined average ODI ≥ 10 with 3% oxygen desaturation determined by wrist oximetry over two nights); and subjective cognitive complaints or mild cognitive impairment. The treatment intervention arm aims to achieve an optimal treatment response based on reducing hypoxic burden with either CPAP, mandibular advancement splint, positional therapy, or oxygen therapy. Furthermore, participants will receive up to 8 sessions which involve motivational interviewing, collaborative goal setting, and behavioural sleep management. The control arm will not receive OSA treatment as part of this trial, however there will be no OSA treatment restrictions, and any treatment will be documented. Primary outcomes are 1) acceptability based upon willingness of participants to be randomised; 2) alleviating hypoxic burden by reducing OSA severity; 3) tolerability of the trial burden based upon collection of outcomes over the 2-year follow-up. Secondary outcomes include safety and cognitive function. Outcomes will be collected at 0, 6 and 24-months. This feasibility study aims to will provide the basis for a larger longer-term trial of dementia prevention.


Asunto(s)
Demencia , Síndromes de la Apnea del Sueño , Apnea Obstructiva del Sueño , Humanos , Anciano , Apnea Obstructiva del Sueño/terapia , Estudios de Factibilidad , Australia , Demencia/prevención & control , Oxígeno , Ensayos Clínicos Controlados Aleatorios como Asunto
6.
J Sleep Res ; : e14088, 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38016812

RESUMEN

Several professional societies have provided recommendations for prescribing medications for insomnia. None has provided an integrative analysis that concurrently quantifies safety and efficacy (e.g., risk-benefit ratios). This represents an important gap for informing clinician decision-making. Accordingly, the aim of the present review is to provide such an analysis for five classes of sleep-promoting medications. Adverse event data values were extracted from the most recent FDA-approved package inserts and converted to an integer before being placebo-adjusted and standardized as a rate per 1000 (AEr). Efficacy data, pre-to-post self-reported data for active and placebo conditions were acquired from pivotal trials identified in "white papers" and systematic reviews/meta-analyses. Weighted effect sizes were calculated for subjective sleep latency, wake time after sleep onset and total sleep time, and then were averaged by medication class for each sleep continuity variable. Overall efficacy was represented by a single variable, SWT (sleep latency + wake time after sleep onset + total sleep time). Risk-benefit was represented using a simple ratio value. For safety, it was found that melatonin receptor agonists had the lowest adverse event rate (AEr = 43.1), and non-benzodiazepine benzodiazepine receptor agonists had the highest rate (AEr = 255.0). For efficacy, it was found that the pre-to-post placebo adjusted effect sizes were largest for benzodiazepines (effect size = 1.94) and smallest for melatonin receptor agonists (effect size = 0.109). For risk-benefit, histamine antagonist had the most favourable profile (risk-benefit = 69.5), while melatonin receptor agonist had the least favourable profile (risk-benefit = 395.7). Overall, the combined metric for risk-benefit suggests that treatment with a histamine antagonist is optimal and potentially represents the best first-line therapy for the medical management of insomnia.

7.
Sleep ; 46(10)2023 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668448

RESUMEN

Obesity is a chronic disease affecting over 670 million adults globally, with multiple complications including obstructive sleep apnea (OSA). Substantial weight loss in patients with obesity-related OSA can reduce or even eliminate OSA as well as reduce sleepiness and improve cardio-metabolic health. Evidence suggests that these improvements exceed those that occur with device-based OSA therapies like continuous positive airway pressure which continue to be the first-line of therapy. Resistance to weight management as a first-line strategy to combat OSA could arise from the complexities in delivering and maintaining adequate weight management, particularly in sleep clinic settings. Recently, incretin-based pharmacotherapies including glucagon-like peptide 1 (GLP-1) receptor agonists alone or combined with glucose-dependent insulinotropic polypeptide (GIP) receptor agonists have been developed to target glycemic control in type 2 diabetes. These medications also slow gastric emptying and reduce energy intake. In randomized, placebo-controlled trials of these medications in diabetic and non-diabetic populations with obesity, participants on active medication lost up to 20% of their body weight, with corresponding improvements in blood pressure, lipid levels, physical functioning, and fat mass loss. Their adverse effects are predominantly gastrointestinal-related, mild, and transient. There are trials currently underway within individuals with obesity-related OSA, with a focus on reduction in weight, OSA severity, and cardio-metabolic outcomes. These medications have the potential to substantially disrupt the management of OSA. Pending coming data, we will need to consider pharmacological weight loss as a first-line therapy and how that influences training and management guidelines.


Asunto(s)
Diabetes Mellitus Tipo 2 , Apnea Obstructiva del Sueño , Adulto , Humanos , Incretinas/uso terapéutico , Incretinas/fisiología , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Obesidad/complicaciones , Obesidad/tratamiento farmacológico , Pérdida de Peso , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/tratamiento farmacológico
8.
BMJ Open ; 13(8): e071148, 2023 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-37612115

RESUMEN

OBJECTIVE: Insomnia is the most prevalent sleep disorder, with few effective pharmacotherapies. Anecdotal reports and recent preclinical research suggest that cannabinol (CBN), a constituent of Cannabis sativa derived from delta-9-tetrahydrocannabinol, could be an effective treatment. Despite this, the isolated effects of CBN on sleep have yet to be systematically studied in humans. METHODS: The present protocol paper describes a randomised, double-blind, placebo-controlled, single-dose, three-arm, cross-over, proof-of-concept study which investigates the effects of CBN on sleep and next-day function in 20 participants with clinician-diagnosed insomnia disorder and an Insomnia Severity Index Score ≥15. Participants receive a single fixed oral liquid dose of 30 mg CBN, 300 mg CBN and matched placebo, in random order on three treatment nights; each separated by a 2-week wash-out period. Participants undergo overnight sleep assessment using in-laboratory polysomnography and next-day neurobehavioural function tests. The primary outcome is wake after sleep onset minutes. Secondary outcomes include changes to traditional sleep staging, sleep-onset latency and absolute spectral power during non-rapid eye movement (NREM) sleep. Tertiary outcomes include changes to sleep spindles during NREM sleep, arousal indices, absolute spectral power during REM sleep and subjective sleep quality. Safety-related and exploratory outcomes include changes to next-day simulated driving performance, subjective mood and drug effects, postural sway, alertness and reaction time, overnight memory consolidation, pre and post-sleep subjective and objective sleepiness; and plasma, urinary, and salivary cannabinoid concentrations. The study will provide novel preliminary data on CBN efficacy and safety in insomnia disorder, which will inform larger clinical trials. ETHICS AND DISSEMINATION: Human Research Ethics Committee approval has been granted by Bellberry (2021-08-907). Study findings will be disseminated in a peer-reviewed journal and at academic conferences. TRIAL REGISTRATION NUMBER: NCT05344170.


Asunto(s)
Trastornos del Inicio y del Mantenimiento del Sueño , Humanos , Trastornos del Inicio y del Mantenimiento del Sueño/tratamiento farmacológico , Cannabinol , Sueño , Polisomnografía , Latencia del Sueño , Ensayos Clínicos Controlados Aleatorios como Asunto
11.
Digit Health ; 9: 20552076231180970, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37377559

RESUMEN

Introduction: While digital health interventions (DHIs) can potentially address the unmet needs for sleep health services, little is known about their implementation in practice. The current study aimed to explore primary care health providers' attitudes and beliefs towards DHIs for sleep and implementation into practice. Methods: A cross-sectional online survey was administered to Australian primary care health professionals: general practitioners (GPs), community nurses, and community pharmacists. Semi-structured interviews were conducted within a sub-sample of participants exploring their experiences with DHIs and perceived barriers/facilitators for embedding DHIs into primary care. Semi-structured interviews were thematically analysed using the framework approach to contextualise survey findings. Results: Ninety-six surveys were returned (GPs = 36, nurses = 30, and pharmacists = 30) and 45 interviews conducted (GPs = 17, nurses = 14, and pharmacists = 14). From the survey, GPs were more likely to endorse familiarity (p = 0.009) and use (p < 0.001) of sleep DHIs in clinical practice than pharmacists and nurses. GPs were more interested in utilising the diagnostic features within a sleep DHI (p = 0.009) compared to other professionals. Thematic analysis of the interviews revealed three major themes, contextualised by profession: (1) Scope for DHIs in Current Practice, (2) Practice Gaps and Training Needs, and (3) Envisioning a Model of Care Using Sleep DHIs. While DHIs can potentially improve care, greater clarity of care pathways and reimbursement structures are needed for integration into practice. Conclusion: Primary care health professionals highlighted the training, care pathway and financial models required to realise the potential for translating findings from efficacy studies for DHIs into primary care to optimise sleep health.

12.
Brain Commun ; 5(3): fcad129, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37234683

RESUMEN

Reduced heart rate variability can be an early sign of autonomic dysfunction in neurodegenerative diseases and may be related to brain dysfunction in the central autonomic network. As yet, such autonomic dysfunction has not been examined during sleep-which is an ideal physiological state to study brain-heart interaction as both the central and peripheral nervous systems behave differently compared to during wakefulness. Therefore, the primary aim of the current study was to examine whether heart rate variability during nocturnal sleep, specifically slow wave (deep) sleep, is associated with central autonomic network functional connectivity in older adults 'at-risk' of dementia. Older adults (n = 78; age range = 50-88 years; 64% female) attending a memory clinic for cognitive concerns underwent resting-state functional magnetic resonance imaging and an overnight polysomnography. From these, central autonomic network functional connectivity strength and heart rate variability data during sleep were derived, respectively. High-frequency heart rate variability was extracted to index parasympathetic activity during distinct periods of sleep, including slow wave sleep as well as secondary outcomes of non-rapid eye movement sleep, wake after sleep onset, and rapid eye movement sleep. General linear models were used to examine associations between central autonomic network functional connectivity and high-frequency heart rate variability. Analyses revealed that increased high-frequency heart rate variability during slow wave sleep was associated with stronger functional connectivity (F = 3.98, P = 0.022) in two core brain regions within the central autonomic network, the right anterior insular and posterior midcingulate cortex, as well as stronger functional connectivity (F = 6.21, P = 0.005) between broader central autonomic network brain regions-the right amygdala with three sub-nuclei of the thalamus. There were no significant associations between high-frequency heart rate variability and central autonomic network connectivity during wake after sleep onset or rapid eye movement sleep. These findings show that in older adults 'at-risk' of dementia, parasympathetic regulation during slow wave sleep is uniquely linked to differential functional connectivity within both core and broader central autonomic network brain regions. It is possible that dysfunctional brain-heart interactions manifest primarily during this specific period of sleep known for its role in memory and metabolic clearance. Further studies elucidating the pathophysiology and directionality of this relationship should be conducted to determine if heart rate variability drives neurodegeneration, or if brain degeneration within the central autonomic network promotes aberrant heart rate variability.

13.
Brain Sci ; 13(4)2023 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-37190578

RESUMEN

Insomnia is a highly prevalent sleep disorder with strong bidirectional associations with depressive symptoms. The circadian preference for eveningness has been shown to be associated with depressive symptoms in insomnia and other mental health conditions. However, there is a lack of studies in insomnia investigating whether objective measures, such as dim light melatonin onset (DLMO) or polysomnographic (PSG) sleep, are associated with depressive symptoms. Therefore, we investigated the associations between subjective measures (questionnaires assessing anxiety, sleep quality and circadian preference, and sleep diary) and depressive symptoms and whether the addition of objective measures (DLMO, PSG parameters) would strengthen the associations with depressive symptoms. In 115 insomnia disorder patients we found that anxiety was strongly associated with depressive symptoms in a model including circadian preference, dysfunctional beliefs of sleep, and self-reported previous depressive symptoms (R2 = 0.496, p < 0.001). The addition of sleep diary measures did not strengthen the model. We also found that the addition of objective measures (DLMO, PSG parameters) did not improve the subjective associations with depressive symptoms. Our data suggest that objective circadian markers are less important in the prediction of depressive symptoms in insomnia compared to subjective measures.

14.
Sleep ; 46(6)2023 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-37052122

RESUMEN

STUDY OBJECTIVES: To compare overnight declarative memory consolidation and non-rapid eye movement (NREM) sleep electroencephalogram (EEG) oscillations in older adults with obstructive sleep apnea (OSA) to a control group and assess slow-wave activity (SWA) and sleep spindles as correlates of memory consolidation. METHODS: Forty-six older adults (24 without OSA and 22 with OSA) completed a word-pair associate's declarative memory task before and after polysomnography. Recall and recognition were expressed as a percentage of the morning relative to evening scores. Power spectral analysis was performed on EEG recorded at frontal (F3-M2, F4-M1) and central (C3-M2, C4-M1) sites. We calculated NREM absolute slow oscillation (0.25-1 Hz) and delta (0.5-4.5 Hz) EEG power, and slow (11-13 Hz) spindle density (number of events per minute of N2 sleep) and fast (13-16 Hz) spindle density. RESULTS: There were no significant differences in overnight recall and recognition between OSA (mean age 58.7 ± 7.1 years, apnea-hypopnea index (AHI) 41.9 ± 29.7 events/hour) and non-OSA (age 61.1 ± 10.3 years, AHI 6.6 ± 4.2 events/hour) groups. The OSA group had lower fast spindle density in the frontal region (p = 0.007). No between-group differences in SWA were observed. In the Control group, overnight recognition positively correlated with slow spindle density in frontal (rho = 0.555, p = 0.020) and central regions (rho = 0.490, p = 0.046). Overnight recall was not related to SWA or spindle measures in either group. CONCLUSIONS: Older adults with OSA had deficits in fast sleep spindles but showed preserved overnight declarative memory consolidation. It is possible that compensatory mechanisms are being recruited by OSA patients to preserve declarative memory consolidation despite the presence of sleep spindle deficits.


Asunto(s)
Consolidación de la Memoria , Apnea Obstructiva del Sueño , Humanos , Anciano , Persona de Mediana Edad , Movimientos Oculares , Sueño , Electroencefalografía
15.
Environ Health Perspect ; 131(3): 37012, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36946580

RESUMEN

BACKGROUND: Large electricity-generating wind turbines emit both audible sound and inaudible infrasound at very low frequencies that are outside of the normal human range of hearing. Sufferers of wind turbine syndrome (WTS) have attributed their ill-health and particularly their sleep disturbance to the signature pattern of infrasound. Critics have argued that these symptoms are psychological in origin and are attributable to nocebo effects. OBJECTIVES: We aimed to test the effects of 72 h of infrasound (1.6-20 Hz at a sound level of ∼90 dB pk re 20µPa, simulating a wind turbine infrasound signature) exposure on human physiology, particularly sleep. METHODS: We conducted a randomized double-blind triple-arm crossover laboratory-based study of 72 h exposure with a >10-d washout conducted in a noise-insulated sleep laboratory in the style of a studio apartment. The exposures were infrasound (∼90 dB pk), sham infrasound (same speakers not generating infrasound), and traffic noise exposure [active control; at a sound pressure level of 40-50 dB LAeq,night and 70 dB LAFmax transient maxima, night (2200 to 0700 hours)]. The following physiological and psychological measures and systems were tested for their sensitivity to infrasound: wake after sleep onset (WASO; primary outcome) and other measures of sleep physiology, wake electroencephalography, WTS symptoms, cardiovascular physiology, and neurobehavioral performance. RESULTS: We randomized 37 noise-sensitive but otherwise healthy adults (18-72 years of age; 51% female) into the study before a COVID19-related public health order forced the study to close. WASO was not affected by infrasound compared with sham infrasound (-1.36 min; 95% CI: -6.60, 3.88, p=0.60) but was worsened by the active control traffic exposure compared with sham by 6.07 min (95% CI: 0.75, 11.39, p=0.02). Infrasound did not worsen any subjective or objective measures used. DISCUSSION: Our findings did not support the idea that infrasound causes WTS. High level, but inaudible, infrasound did not appear to perturb any physiological or psychological measure tested in these study participants. https://doi.org/10.1289/EHP10757.


Asunto(s)
COVID-19 , Centrales Eléctricas , Humanos , Adulto , Femenino , Masculino , Estudios Cruzados , Ruido/efectos adversos , Sueño
16.
Chest ; 163(2): e105-e106, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36759116
17.
Clin Interv Aging ; 18: 49-59, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36660543

RESUMEN

Exogenous melatonin is commonly used for sleep disorders in older adults, and its use is increasing over time. It appears to have modest efficacy in treating insomnia and circadian rhythm sleep-wake disorders. Melatonin is commonly perceived to be a safe alternative to other hypnotics and is available without prescription in some jurisdictions. New evidence suggests that endogenous melatonin has pleomorphic effects on multiple organ systems, many of which are poorly understood. This narrative review summarizes the current evidence regarding the safety of melatonin in older adults (defined by age over 65 years). Melatonin appears to have a favorable safety profile in this population, however there is a dearth of evidence regarding the safety of prolonged use. There are several factors which increase the risk of adverse effects of melatonin in older adults, and these should be taken into consideration when prescribing to this population.


Asunto(s)
Melatonina , Trastornos del Sueño del Ritmo Circadiano , Trastornos del Inicio y del Mantenimiento del Sueño , Trastornos del Sueño-Vigilia , Humanos , Anciano , Sueño , Melatonina/efectos adversos , Trastornos del Inicio y del Mantenimiento del Sueño/tratamiento farmacológico , Hipnóticos y Sedantes/efectos adversos , Trastornos del Sueño-Vigilia/tratamiento farmacológico , Ritmo Circadiano , Trastornos del Sueño del Ritmo Circadiano/tratamiento farmacológico
18.
Ann Am Thorac Soc ; 20(4): 584-595, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36538809

RESUMEN

Rationale: The combination of noradrenergic and antimuscarinic agents has recently been shown to improve upper-airway function and reduce obstructive sleep apnea (OSA) severity in short-term (⩽1 wk) proof-of-concept studies. Objectives: To determine the safety, tolerability, and potential efficacy of longer term use of different doses of the noradrenergic agent atomoxetine combined with the antimuscarinic oxybutynin (ato-oxy). Methods: Thirty-nine people with predominantly severe OSA received 80/5 mg ato-oxy, 40/5 mg ato-oxy, 40/2.5 mg ato-oxy, or placebo nightly for 30 days in a double-blind, randomized, parallel design. Participants completed three in-laboratory sleep studies (baseline, Night 1, and Night 30) to assess efficacy. Vital signs and objective measures of alertness and memory were assessed. In men, potential effects on prostate function were assessed using the International Prostate Symptom Score at baseline and Night 30. Potential adverse events were assessed during in-laboratory visits and via weekly phone calls. Results: Side effects were generally mild and consistent with known side-effect profiles of each individual drug (i.e., dose-dependent increases in dry mouth with oxybutynin). Heart rate increased by Night 30 in two active drug arms (mean ± standard deviation 8 ± 10 beats/min [P = 0.01] with 80/5 mg and 9 ± 14 beats/min [P = 0.02] with 40/2.5 mg vs. placebo). No clinically relevant changes in blood pressure, International Prostate Symptom Score, and measures of alertness and memory were observed between conditions. Apnea-hypopnea index (AHI) with 4% oxygen desaturation and hypoxic burden decreased by ∼50% with 80/5 mg ato-oxy from baseline but not versus placebo (e.g., AHI with 3% oxygen desaturation and AHI with 4% oxygen desaturation difference at Night 30 was -8.2 [95% confidence interval, -22.5 to 6.2] and -8.5 [95% confidence interval, -18.3 to 1.3] events/h, respectively). Conclusions: One month of nightly noradrenergic and antimuscarinic combination therapy was generally well tolerated, with a side-effect profile consistent with each agent alone, and was associated with an ∼50% reduction from baseline in a key OSA severity metric, the hypoxic burden with the highest dose combination. These findings highlight the potential to target noradrenergic and antimuscarinic mechanisms for OSA pharmacotherapy development. Clinical trial registered with www.anzctr.org.au (ACTRN 12619001153101).


Asunto(s)
Antagonistas Muscarínicos , Apnea Obstructiva del Sueño , Masculino , Humanos , Clorhidrato de Atomoxetina/efectos adversos , Antagonistas Muscarínicos/efectos adversos , Apnea Obstructiva del Sueño/tratamiento farmacológico , Oxígeno/uso terapéutico
19.
Drug Test Anal ; 15(3): 334-344, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36478641

RESUMEN

A growing number of clinical trials (CTs) are investigating the therapeutic potential of cannabidiol (CBD), a non-intoxicating phytocannabinoid found in Cannabis sativa. These CTs often use crossover experimental designs requiring 'washout' (clearance) periods. However, the length of time CBD persists in plasma (its 'window of detection') is unclear and could be significant. Indeed, the structurally related phytocannabinoid, Δ9 -tetrahydrocannabinol (THC), has a long window of detection in plasma. We investigated the extent to which CBD and its major metabolites persist in plasma. Data from three CTs that measured plasma cannabinoid concentrations ≥7 days after administering a single oral dose of CBD were pooled. The CBD doses were as follows: CT #1: 300 mg; CT #2: 200 mg (and 10 mg THC); and CT #3: 15, 300 and 1500 mg (one per treatment session). Thirty-two participants were included in the analysis, 17 of whom (from CT #3) provided repeated measures. Overall, 0% (15 mg), 60% (200 mg), 28% (300 mg) and 100% (1500 mg) of participants had detectable concentrations (i.e., >0.25 ng·ml-1 ) of CBD in plasma ≥7 days post-treatment (some, several weeks post-treatment). A zero-inflated negative binomial mixed-effects regression analysis (R2 m = 0.44; R2 c = 0.73) predicted that, on average, a 13 day washout period would reduce plasma CBD concentrations to 'zero' (i.e., <0.25 ng·ml-1 ) if a single oral dose of 300 mg was consumed. Higher doses require longer washout periods; concomitant medications may also affect clearance. In conclusion, CBD has a long window of detection in plasma. Crossover studies involving CBD should, therefore, be conducted with caution, particularly when higher doses and/or chronic dosing regimens are used.


Asunto(s)
Cannabidiol , Cannabinoides , Cannabis , Humanos , Cannabidiol/análisis , Dronabinol/análisis , Cannabinoides/análisis , Método Doble Ciego
20.
J Clin Sleep Med ; 19(1): 85-96, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36004739

RESUMEN

STUDY OBJECTIVES: Recent findings indicate that noradrenergic and muscarinic processes are crucial for pharyngeal muscle control during sleep. However, to date, reductions in obstructive sleep apnea (OSA) severity have only been detected when noradrenergic agents are combined with an antimuscarinic. Accordingly, this study aimed to determine if reboxetine alone and combined with oxybutynin reduces OSA severity. The pathophysiological mechanisms underpinning the effects of these agents were also investigated via endotyping analysis. METHODS: Sixteen people (6 women) with OSA completed 3 polysomnograms (∼1-week washout) according to a double-blind, placebo-controlled, three-way crossover design across 2 sites. Single doses of 4 mg reboxetine, placebo, or 4 mg reboxetine + 5 mg oxybutynin were administered before sleep (order randomized). RESULTS: Reboxetine reduced the apnea-hypopnea index (primary outcome) by 5.4 (95% confidence interval -10.4 to -0.3) events/h, P = .03 (-24 ± 27% in men; -0.7 ± 32% in women). Oxybutynin did not cause additional reductions in apnea-hypopnea index. Reboxetine alone reduced the 4% oxygen desaturation index by (mean ± standard deviation) 5.2 ± 7.2 events/h and reboxetine+oxybutynin by 5.1 ± 10.6 events/h vs placebo, P = .02. Nadir oxygen saturation also increased by 7 ± 11% with reboxetine and 5 ± 9% with reboxetine+oxybutynin vs placebo, P = .01. Mechanistically, reboxetine and reboxetine+oxybutynin improved pharyngeal collapsibility and respiratory control (loop gain). Larger reductions in apnea-hypopnea index with reboxetine in men were associated with higher baseline loop gain. CONCLUSIONS: These findings show the first evidence that reboxetine alone reduces OSA severity. The data provide novel insight into the role of norepinephrine reuptake inhibitors on upper airway stability during sleep and are important to inform future pharmacotherapy development for OSA. CLINICAL TRIAL REGISTRATION: Registry: Australian New Zealand Clinical Trials Registry; Name: Reboxetine and Combination Therapy with AD128 in Sleep Apnoea Trial: A Double-Blind, 3-Way Cross-Over Study; URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=374614&isReview=true; Identifier: ACTRN12620000662965. CITATION: Altree TJ, Aishah A, Loffler KA, Grunstein RR, Eckert DJ. The norepinephrine reuptake inhibitor reboxetine alone reduces obstructive sleep apnea severity: a double-blind, placebo-controlled, randomized crossover trial. J Clin Sleep Med. 2023;19(1):85-96.


Asunto(s)
Apnea Obstructiva del Sueño , Masculino , Humanos , Femenino , Estudios Cruzados , Reboxetina/uso terapéutico , Australia , Apnea Obstructiva del Sueño/terapia , Método Doble Ciego
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...